F-220609-1008-1

Bulk Current Injection (BCI) Probe by Fischer Custom Communications (28 more products)
Request Quote

Note: Your Quotation Request will be directed to Fischer Custom Communications.

The F-220609-1008-1 from Fischer Custom Communications is a Bulk Current Injection (BCI) Probe with Frequency 10 kHz to 400 MHz, CW Current 100 to 500 A, Max input power 250 to 500 W, Height/Thickness 134 mm. More details for F-220609-1008-1 can be seen below.

Product Specifications

Product Details

  • Part Number :
    F-220609-1008-1
  • Manufacturer :
    Fischer Custom Communications
  • Description :
    Bulk Current Injection Probes from 10 kHz to 400 MHz

General Parameters

  • Frequency :
    10 kHz to 400 MHz
  • CW Current :
    100 to 500 A
  • Inner Diameter :
    40 mm
  • Outer Diameter :
    127 mm
  • Max input power :
    250 to 500 W
  • Applications :
    Conducted Immunity Testing
  • Duration :
    15 to 30 min
  • Height/Thickness :
    134 mm