CDN T2

Coupling Decoupling Network by 3Ctest (52 more products)
Request Quote

Note: Your Quotation Request will be directed to 3Ctest.

The CDN T2 from 3Ctest is a Coupling Decoupling Network with Frequency 150 kHz to 80 MHz, Operating Voltage 60 VAC, 100 VDC, Operating Current 0.5 A. More details for CDN T2 can be seen below.

Product Specifications

Product Details

  • Part Number
    CDN T2
  • Manufacturer
    3Ctest
  • Description
    Coupling/Decoupling Networks for Unscreened Symmetrical Lines

General Parameters

  • Frequency
    150 kHz to 80 MHz
  • Cable Type
    Unscreened
  • Number of Lines
    2 Lines
  • EMC Standards
    IEC61000-4-6, EN 61000-4-6, GB/T17626.6
  • Common Mode Impedance
    150 Ohms
  • Decoupling Attenuation
    40 to 60 dB
  • Voltage Division Factor
    9.5 dB
  • Operating Voltage
    60 VAC, 100 VDC
  • Operating Current
    0.5 A
  • Dimensions
    210 x 170 x 115 mm
  • Connector AE
    4 mm Banana Plug
  • Connector EUT
    4 mm Banana Plug
  • Applications
    Communication, IT, Telecom, Military, Medical, Avionics, Broadcast, New Energy, Railway
  • Operating Temperature
    15 to 35 Degree C
  • Weight
    4 kg
View more details on the manufacturer's website

Technical Articles

1017 Coupling Decoupling Network 52 1017_52_cdn_t2 coupling_decoupling_networks viewmore ../ ../../../../ equipment1 ../ 1017
Need Help Finding a Product?