Note: Your Quotation Request will be directed to
3Ctest.
The CDN 418TH8 from 3Ctest is a Coupling Decoupling Network with Operating Voltage 90 VDC, Surge Voltage 4 kV, Operating Current 1 A. More details for CDN 418TH8 can be seen below.
Product Specifications
Product Details
Part Number
CDN 418TH8
Manufacturer
3Ctest
Description
Coupling/Decoupling Networks for Damped Oscillatory Waves testing on Unshielded Symmetrical High-Speed Communication Lines
General Parameters
Type
Telecommunication Line
Pulse Type
Surge
Cable Type
Unshielded
Number of Lines
8 Lines
EMC Standards
IEC / EN 61000 -4 -18
Decoupling Chokes
20 mH
Operating Voltage
90 VDC
Surge Voltage
4 kV
Operating Current
1 A
Dimensions
360 x 220 x 135 mm
Connectors
RJ45 Female
Applications
Communication, IT, Telecom, Military, Medical, Avionics, Broadcast, New Energy, Railway