Note: Your Quotation Request will be directed to Com-Power Corporation.
The CLCI-100 from Com-Power Corporation is a Bulk Current Injection Probe operating from 10 kHz to 100 MHz. It is designed to inject/monitor RF current onto a wire, cable, or cable bundle. It has a window diameter of 40 mm and an outside diameter of 146 mm. This probe incorporates split-core ferrites into its rugged, circular enclosure, and is hinged thereby allowing the probe to be opened on one side in order to easily place the wire, cable(s) or cable bundle(s) to be tested into the probe window. It can be employed WITH Com-Power's FCLC-100 Calibration Fixture, ADA-515-2 150 ohm to 50 ohm Adapters, Term-50-100W Power Terminator and ASC Series Power Amplifiers.
The CLCI-100 is compliant to IEC 61000-4-6 and CISPR 16-1-2 and is ideal for use in conjunction with spectrum analyzer or EMI receiver, which measure magnitude quantities in terms of true rms voltage. It is available in an enclosure that measures 40 x 146 x 70 mm with N-type female connectors.